Start with the symptoms

Borescope inspection of concealed roof-to-wall cavities

A small inspection camera can follow a stain into a concealed cavity at the edge of a roof. It is especially useful when a finished ceiling or wall hides the junction under investigation.

Water staining on an exposed interior surface near piping.
Diamond field photograph · Tracing an interior stain

When a camera can answer a question

Consider a leak at the inside face of a parapet that returns after the field membrane has been patched. A camera view behind an accessible finish may show a water trail on the wall side of the junction, directing the exterior investigation toward a coping joint or wall flashing. Other clues include beads on a cold pipe, discolored sheathing or insulation visibly slumped beneath a drip. Their position relative to the roof edge or equipment matters.

Understand the view and its limits

An investigator uses an existing access point or arranges an authorized small opening after checking for concealed services and other hazards. The report should identify the opening and the direction of each photograph. The lens sees exposed surfaces within reach. A dry-looking cavity on one visit cannot establish that neighboring roof boards are dry. An optical image also cannot measure how much water a board contains or establish when an old stain formed.

Use what the camera finds

A visible drip during rain gives a specific detail to trace or test. If dampness is beside a cold duct, compare the local dew point and duct temperature. If water tracks lead toward a roof section, use a compatible survey and a targeted core to decide whether insulation removal is warranted. Restore any opening and affected air, vapor or fire-control layers, then revisit the original location after the source repair.

Repair and mitigation options for a wet roof
Stop water at its source
Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
Correct ponding and poor drainage
Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
Remove wet insulation and damaged board
Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
Control condensation and indoor moisture
Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
Use one-way pressure-relief vents only where specified
A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
Verify drying, replacement or restoration
Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.
Read the complete mitigation guide

Technical references

Continue your investigation

Request an assessment

Tell us where the property is and what needs attention. Roof inspections and estimates are free, with measurements, photos, a video walkthrough and drone views included. You’ll receive a request reference number.

Add address, timing or project details (optional)