Locate a water-entry path

High-voltage dry roof membrane testing

A specialist can use a dry electrical sweep, sometimes called holiday testing, to find tiny through-openings in certain exposed sheet or fluid-applied membranes.

White seam treatment around a rooftop equipment curb on the Anderson roof.
Diamond field photograph · Seam and flashing repairs

When a dry sweep helps

Consider a puncture after another trade moved equipment across a newly waterproofed area. An electrode passing over the exposed, dry surface can produce a localized signal where electricity crosses an opening to the conductive substrate beneath. Marking that spot lets the roofer inspect a defect that may be difficult to see.

What can invalidate the signal

Membrane type, thickness and the position of the conductive layer determine suitability. Conventional high-voltage testing is unsuitable for conductive black EPDM. Surface water, metal terminations, varying coating thickness and inaccessible areas complicate the survey. An overlapping seam can hide a sideways water path that the dry electrical sweep misses.

The testing specialist confirms the manufacturer's acceptance and the instrument setting for the installed membrane. Excessive voltage can damage material. Coverage and any details checked by a different method belong on the survey plan.

What the result means for restoration

A confirmed pinhole calls for a compatible repair and repeat integrity test. Where the opening may have admitted water over time, compare the surrounding insulation with a dry reference, then sample to establish the repair boundary. A successful repeat sweep confirms the tested repair under those conditions. It does not establish that previously wet layers have dried.

Repair and mitigation options for a wet roof
Stop water at its source
Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
Correct ponding and poor drainage
Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
Remove wet insulation and damaged board
Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
Control condensation and indoor moisture
Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
Use one-way pressure-relief vents only where specified
A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
Verify drying, replacement or restoration
Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.
Read the complete mitigation guide