When the roof can carry the fog
The test needs a connected space below the membrane and a sufficiently airtight lower boundary. On mechanically attached roofs, the fastening pattern may divide the roof into narrow strips. Full adhesion, separate compartments and compressed insulation can stop the fog from reaching the area of interest. A specialist reviews the original assembly and limits the test to a defined area.
Interpreting what comes out
A visible plume at a split or seam marks an air path worth inspecting. An outlet at a known vent or open perimeter can simply show where the fog traveled. Wind, poor distribution or a small opening can make a plume hard to see. Confirm which sections actually received fog before drawing conclusions from a quiet area.
Protecting the roof during diagnosis
Coordinate the investigation with building operations, nearby air intakes and alarm procedures. The specialist manages the test pressure and makes a compatible permanent repair at any temporary access opening. Inspect the indicated defect, address the route for rain entry and assess retained moisture separately. Smoke cannot establish how far water migrated beneath the roof or which insulation boards need replacement.
Repair and mitigation options for a wet roof
- Stop water at its source
- Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
- Correct ponding and poor drainage
- Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
- Remove wet insulation and damaged board
- Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
- Control condensation and indoor moisture
- Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
- Use one-way pressure-relief vents only where specified
- A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
- Verify drying, replacement or restoration
- Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.