Locate a water-entry path

Tracer gas testing for concealed membrane openings

A sensor can detect a test gas emerging through a roof membrane. This specialist technique can narrow a stubborn leak investigation when the construction allows gas to travel beneath the sheet.

Aerial view of a white commercial roof bordered by trees.
Diamond field photograph · Visible-light aerial view

What the detector measures

In a compatible roof section, a specialist introduces a selected tracer beneath the membrane, then surveys above it for a signal above the background level. The sensor can find a gas pathway where a visual inspection showed little. The technician checks the surface around each indication to identify an actual opening.

Reading weak and missing signals

A usable result depends on the gas reaching the suspected detail. Mechanically attached membranes with a connected space underneath are better candidates than sheets bonded continuously to their substrate. Compartments, cover layers, outlets and airflow influence where gas is detectable. A concentration at the surface narrows the investigation. It cannot say how much water entered, how long it has been there or how large the wet area is.

What to ask for before approving repairs

Ask how the test area will be isolated, what occupancy and ventilation arrangements apply, and how access points will be resealed. The report should identify the area surveyed, the observed outlet and the membrane defect actually verified. Repair the confirmed defect, then use a suitable moisture survey and targeted verification where a long-standing leak may have affected boards or decking.

Repair and mitigation options for a wet roof
Stop water at its source
Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
Correct ponding and poor drainage
Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
Remove wet insulation and damaged board
Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
Control condensation and indoor moisture
Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
Use one-way pressure-relief vents only where specified
A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
Verify drying, replacement or restoration
Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.
Read the complete mitigation guide

Technical references

Continue your investigation

Request an assessment

Tell us where the property is and what needs attention. Roof inspections and estimates are free, with measurements, photos, a video walkthrough and drone views included. You’ll receive a request reference number.

Add address, timing or project details (optional)