Locate a water-entry path

Low-voltage electronic roof leak detection

A wet low-voltage survey can locate an opening in a compatible waterproof membrane. It helps when a small puncture leaves few visible clues or a new roof is about to be covered.

White seam treatment around a rooftop equipment curb on the Anderson roof.
Diamond field photograph · Seam and flashing repairs

What the technician looks for

Water on the membrane creates an electrical path through a breach to a conductive layer beneath it. With electric field vector mapping, the technician follows changes in the field toward the opening. A scanning platform instead checks the exposed surface that it passes over. Handheld equipment can check compatible vertical flashing.

Which assemblies can be tested

The return path matters. A metal deck several inches below dry foam insulation does not by itself make the roof testable. The technician needs to identify the membrane and the conductive substrate or approved conductive layer directly beneath it. Black EPDM and other conductive materials need system-specific review. On an occupied roof, metal details and inaccessible areas should appear in the coverage record.

A scanning platform needs direct contact. Some vector surveys can investigate through suitable overburden, but pavers, planting and other layers complicate interpretation. When possible, arrange integrity testing before these materials cover the membrane.

From a marked breach to a repair

Ask for a roof plan with verified openings, exclusions and the result of retesting each repair. A breach above an old ceiling stain deserves investigation even if the interior is dry on test day. To price insulation removal, map the surrounding area separately and verify suspect and comparison locations by sampling.

Repair and mitigation options for a wet roof
Stop water at its source
Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
Correct ponding and poor drainage
Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
Remove wet insulation and damaged board
Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
Control condensation and indoor moisture
Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
Use one-way pressure-relief vents only where specified
A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
Verify drying, replacement or restoration
Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.