How an open seam appears
At a heat-welded lap, adjoining thermoplastic sheets should fuse to one another. A trained roofer checks cooled welds with a suitable blunt probe and looks for places where it enters between the sheets. Changes from machine welding to hand work, T-joints and areas over board joints deserve attention. A loose edge or wrinkle is a reason to check closely.
What the test covers
The technique follows the membrane maker's instructions, which differ for TPO and PVC. It examines the accessible weld edge. It cannot inspect concealed lower roofs, establish moisture content or exclude a field puncture several feet from the seam. A seam probe is different from a pin moisture meter. One checks the connection between sheets and the other measures an electrical response within material.
Document a repair that will last
Have the roofer mark each failed weld on the roof plan and select an approved repair detail appropriate for the age and condition of the sheet. Confirm the repaired seam after cooling. For a weathered open seam above an occupied space, investigate the dimensions of any wet insulation before setting the patch or replacement scope. Photographs of the opened area help the owner understand what was removed.
Repair and mitigation options for a wet roof
- Stop water at its source
- Repair confirmed openings at seams, flashings, curbs, drains or penetrations with a detail suited to the existing membrane. Refer leaking drain piping or HVAC condensate equipment to the appropriate trade. Check the repair under the conditions that produced the leak.
- Correct ponding and poor drainage
- Clear and maintain drains, scuppers and gutters. Persistent low spots can call for tapered insulation, crickets or changes to outlet elevations. Have suspected deflection or deck damage evaluated before adding material or load.
- Remove wet insulation and damaged board
- Mark the verified boundary, expose the affected layers, and extend removal to sound, dry material. Evaluate the deck and fasteners, replace unsuitable insulation and cover board, and tie the compatible waterproofing back into the surrounding roof.
- Control condensation and indoor moisture
- Trace humid air, duct leakage and cold surfaces. Address exhaust, air sealing, insulation continuity or vapor control according to the building and climate. Recheck humidity and surface conditions during the operating cycle that produced the wetting.
- Use one-way pressure-relief vents only where specified
- A one-way vent can release vapor pressure from a compatible roof assembly. Its effect depends on a path for vapor to reach it. A vent cannot restore a crushed board, remove standing water or establish that saturated insulation is dry. Obtain the system designer’s or manufacturer’s detail.
- Verify drying, replacement or restoration
- Where an approved drying plan applies, document readings against suitable dry reference areas before closing the work. Broader wetting, repeated leaks or compromised decking can warrant sectional or full replacement. Confirm a dry, sound substrate and coating compatibility before restoration.